CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION

CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION
Author :
Publisher :
Total Pages : 156
Release :
ISBN-10 : OCLC:492174786
ISBN-13 :
Rating : 4/5 (86 Downloads)

Book Synopsis CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION by : DAVID.. CHEVREAU

Download or read book CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION written by DAVID.. CHEVREAU and published by . This book was released on 2000 with total page 156 pages. Available in PDF, EPUB and Kindle. Book excerpt: LES CONVERTISSEURS STATIQUES SONT SUSCEPTIBLES DE GENERER DES NIVEAUX ELEVES DE PERTURBATIONS ELECTROMAGNETIQUES, SUR UNE GAMME FREQUENTIELLE ETENDUE. EN BASSE FREQUENCE, ILS POSENT LE PROBLEME DE LA POLLUTION HARMONIQUE, QUI FAIT L'OBJET DE CE MEMOIRE. LES EFFETS NEFASTES DES HARMONIQUES DE COURANT SONT RAPPELES : SURDIMENSIONNEMENT, VIEILLISSEMENT PREMATURE DU MATERIEL, ETC. POUR CES RAISONS, DIVERSES NORMES LIMITANT LES EMISSIONS HARMONIQUES SONT ENTREES EN VIGUEUR. LA NORME EN 61000-3-2 (APPAREILS DE MOINS DE 16 A PAR PHASE), EST ANALYSEE. ELLE EST SI CONTRAIGNANTE QUE LE CLASSIQUE REDRESSEUR MONOPHASE A DIODES EST SYSTEMATIQUEMENT HORS NORMES DES QUE SA PUISSANCE DEPASSE QUELQUES KILOWATTS. NOUS MONTRONS QU'IL EST SOUHAITABLE, DANS LA MESURE OU AUCUNE SOLUTION CORRECTIVE REELLEMENT SATISFAISANTE N'EXISTE (FILTRAGE ACTIF OU PASSIF), DE LIMITER LA POLLUTION HARMONIQUE A SA SOURCE, EN DEVELOPPANT DE NOUVEAUX TYPES DE CONVERTISSEURS A ABSORPTION QUASI-SINUSOIDALE DE COURANT. DIVERS CONVERTISSEURS AC/DC MONOPHASES PEU POLLUANTS SONT PRESENTES. UNE ANALYSE DETAILLEE DE LEURS QUALITES ET DEFAUTS EST REALISEE. DEUX CONVERTISSEURS SONT RETENUS POUR DES ETUDES ULTERIEURES : UN MONTAGE CLASSIQUE (REDRESSEUR A DIODES ET HACHEUR DE BOOST), ET UN MONTAGE EN PONT COMPLET PEU REPANDU EN CONVERSION AC/DC. LES PRINCIPES DE COMMANDE DE CES CONVERTISSEURS SONT ENSUITE PRESENTES. LES PRINCIPAUX CIRCUITS INTEGRES DEDIES A LA COMMANDE SONT ETUDIES, ET LEURS LIMITATIONS EXPLICITEES. UNE COMMANDE ORIGINALE EST ENSUITE PROPOSEE ET VALIDEE EN SIMULATION SUR LES CONVERTISSEURS MENTIONNES CI-DESSUS. LES SIMULATIONS MONTRENT LES EXCELLENTES PERFORMANCES DE LA COMMANDE ET LA SUPERIORITE INTRINSEQUE DU CONVERTISSEUR EN PONT SUR LE CONVERTISSEUR CLASSIQUE. LES CONCLUSIONS DEDUITES DES SIMULATIONS SONT CONFIRMEES PAR LES RESULTATS EXPERIMENTAUX OBTENUS SUR DEUX PROTOTYPES. ENFIN, UNE COMMANDE ORIGINALE, BASEE SUR LA PASSIVITE ET PROPOSEE PAR LE LSS, EST VALIDEE SUR CES CONVERTISSEURS.


CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION Related Books

CONTRIBUTION A L'ANALYSE ET A LA REDUCTION DE LA POLLUTION HARMONIQUE GENEREE PAR LES CONVERTISSEURS STATIQUES SUR LE RESEAU DE DISTRIBUTION
Language: fr
Pages: 156
Authors: DAVID.. CHEVREAU
Categories:
Type: BOOK - Published: 2000 - Publisher:

DOWNLOAD EBOOK

LES CONVERTISSEURS STATIQUES SONT SUSCEPTIBLES DE GENERER DES NIVEAUX ELEVES DE PERTURBATIONS ELECTROMAGNETIQUES, SUR UNE GAMME FREQUENTIELLE ETENDUE. EN BASSE
Optimisation adaptative pour le filtrage global des perturbations harmoniques dans les réseaux électriques
Language: fr
Pages: 258
Authors: Patrick Béguery
Categories:
Type: BOOK - Published: 1996 - Publisher:

DOWNLOAD EBOOK

DANS LE CADRE DE RESEAUX DE DISTRIBUTION ELECTRIQUE DE PLUS EN PLUS COMPLEXES, LES SOLUTIONS EXISTANTES POUR LE MAINTIEN DE LA QUALITE DE L'ENERGIE, ET EN PARTI
Impact de la pollution harmonique sur les matériels de réseau
Language: fr
Pages: 156
Authors: Wilfried Frelin
Categories:
Type: BOOK - Published: 2009 - Publisher:

DOWNLOAD EBOOK

La prolifération sur les réseaux électriques de charges non linéaires entraîne une augmentation des taux de distorsion harmonique. Ces charges non linéair
Convertisseurs statiques AC-DC triphasés à facteur de puissance quasi unitaire
Language: fr
Pages: 208
Authors: Abdennebi El Hasnaoui
Categories:
Type: BOOK - Published: 1997 - Publisher:

DOWNLOAD EBOOK

Contribution à l'analyse des systèmes électrotechniques complexes
Language: fr
Pages: 0
Authors: Alain Groud
Categories:
Type: BOOK - Published: 2013 - Publisher:

DOWNLOAD EBOOK

Les systèmes électrotechniques complexes tels qu'une chaîne électromécanique sont formés de plusieurs éléments de natures différentes (convertisseurs s